Quick Answer
Calculate ASHRAE 183/RTS Zone Cooling Load (Sensible + Latent)
Calculator
Need Equipment or a Supplier for This Project?
Use your calculation result to continue with equipment selection, supplier discovery, engineering support, or project evaluation.
Find Engineering Solutions →Result Interpretation
ASHRAE 183/RTS Zone Cooling Load (Sensible + Latent) calculator computes Total zone cooling load in W using the defined engineering formula and the input values provided. Total zone cooling load is expressed in W. No universal acceptance threshold is defined by this calculator.
Worked Example
Verified calculation
Given:
- Conduction heat gain = 1250
- Solar radiation heat gain = 2100
- Internal sensible heat gain = 850
- Internal latent heat gain = 320
- Infiltration sensible heat gain = 410
- Ventilation sensible + latent heat gain = 680
Expected Result:
- Total zone cooling load = 5610
Engineering Interpretation:
Under the given input conditions, the calculated result is: Total zone cooling load = 5610 W.
The actual numerical result is computed by the Runtime engine using the persisted tool definition. The values shown here come from automatically validated test cases.
Formula / Method
total zone cooling load = conduction heat gain + solar radiation heat gain + internal sensible heat gain + internal latent heat gain + infiltration sensible heat gain + ventilation sensible + latent heat gainFormula family: formula_hvac_hvac_cooling_load_calculation_per_zone_ashrae_183rts_method
Variables
| Symbol | Label | Role | Description |
|---|---|---|---|
| Q_cond | Conduction heat gain | INPUT | Conduction heat gain |
| Q_solar | Solar radiation heat gain | INPUT | Solar radiation heat gain |
| Q_int_sen | Internal sensible heat gain | INPUT | Internal sensible heat gain |
| Q_int_lat | Internal latent heat gain | INPUT | Internal latent heat gain |
| Q_infil | Infiltration sensible heat gain | INPUT | Infiltration sensible heat gain |
| Q_vent | Ventilation sensible + latent heat gain | INPUT | Ventilation sensible + latent heat gain |
| cooling_load | Total zone cooling load | OUTPUT | Total zone cooling load |
Calculation Steps
- Enter the conduction heat gain in W.
- Enter the solar radiation heat gain in W.
- Enter the internal sensible heat gain in W.
- Enter the internal latent heat gain in W.
- Enter the infiltration sensible heat gain in W.
- Enter the ventilation sensible + latent heat gain in W.
- Step 1: Compute total zone cooling load.
- Read the total zone cooling load (W) from the results.
Engineering Summary
Calculate ASHRAE 183/RTS Zone Cooling Load (Sensible + Latent)
Frequently Asked Questions
What does this calculator calculate?
The ASHRAE 183/RTS Zone Cooling Load (Sensible + Latent) calculator estimates Total zone cooling load based on the input parameters you provide
Why is conduction heat gain important in this calculation?
conduction heat gain is directly proportional to total zone cooling load. When you enter conduction heat gain in W, the calculator uses it in the engineering formula to compute the output
How should I interpret the result total zone cooling load?
The calculator outputs total zone cooling load in W. For larger power values, divide by 1000 to express the result in kW, or by 745.7 for horsepower. The result is computed directly from the input values using the defined engineering formula
What units should I use for the inputs?
Enter each value in the units shown next to the input field: Conduction heat gain (W), Solar radiation heat gain (W), Internal sensible heat gain (W), Internal latent heat gain (W), Infiltration sensible heat gain (W), Ventilation sensible + latent heat gain (W). Make sure all inputs use the specified units for consistent results
What assumptions does this calculator use?
This calculator uses automatically validated engineering formulas. Results are approximate and should be validated against site-specific conditions, applicable codes, and professional engineering judgment
Related Tools
Browse More Tools